Quality Control: Difference between revisions

From XDSwiki
Jump to navigation Jump to search
Line 9: Line 9:
Reference: Köhler, R., Schäfer, K., Müller, S., Vignon, G., Diederichs, K., Philippsen, A., Ringler, P., Pugsley, A.P., Engel, A., Welte, W. (2004) Structure and assembly of the pseudopilin PulG. ''Molecular Microbiology'' '''54''', 647-664.
Reference: Köhler, R., Schäfer, K., Müller, S., Vignon, G., Diederichs, K., Philippsen, A., Ringler, P., Pugsley, A.P., Engel, A., Welte, W. (2004) Structure and assembly of the pseudopilin PulG. ''Molecular Microbiology'' '''54''', 647-664.
[http://dx.doi.org/10.1111/j.1365-2958.2004.04307.x]
[http://dx.doi.org/10.1111/j.1365-2958.2004.04307.x]
=== XDS.INP for remote high data ===
JOB=XYCORR INIT COLSPOT IDXREF DEFPIX INTEGRATE CORRECT
! for this experiment:
ORGX=1031 ORGY=1001
DETECTOR_DISTANCE=220
OSCILLATION_RANGE=1
X-RAY_WAVELENGTH=0.97857
NAME_TEMPLATE_OF_DATA_FRAMES=images/pulg_semet_D22_2_???.img DIRECT  TIFF
DATA_RANGE=5 124
SPOT_RANGE=5 124
SPACE_GROUP_NUMBER=179
UNIT_CELL_CONSTANTS= 85.5  85.5  145.2  90 90 120
FRIEDEL'S_LAW=FALSE
STRICT_ABSORPTION_CORRECTION=TRUE
! parameters with changes wrt default values:
VALUE_RANGE_FOR_TRUSTED_DETECTOR_PIXELS=8000. 30000.
MINIMUM_ZETA=0.05
INCLUDE_RESOLUTION_RANGE=50 0
STRONG_PIXEL=6
BACKGROUND_RANGE=1 10
! parameters specifically for this detector and beamline:
NX=2048 NY=2048 QX=0.079092  QY=0.079092  !MARCCD 165mm version
DETECTOR=CCDCHESS        MINIMUM_VALID_PIXEL_VALUE=0    OVERLOAD=65000
DIRECTION_OF_DETECTOR_X-AXIS=1 0 0
DIRECTION_OF_DETECTOR_Y-AXIS=0 1 0
INCIDENT_BEAM_DIRECTION=0 0 1
ROTATION_AXIS=1 0 0
FRACTION_OF_POLARIZATION=0.99
POLARIZATION_PLANE_NORMAL=0 1 0
=== XDS.INP for inflection point data ===
same as above, except
X-RAY_WAVELENGTH=0.97972
NAME_TEMPLATE_OF_DATA_FRAMES=images/pulg_semet_D22_3_???.img DIRECT  TIFF
DATA_RANGE=1 120
SPOT_RANGE=1 120

Revision as of 19:00, 22 January 2008

This is an attempt of putting together a number of datasets with different characteristics (high and low resolution, good and bad crystals, untwinned and twinned), their evaluation with different versions of XDS, and the determination of the quality of the resulting data using refinement and phasing. The goal of this project is to find generally optimal parameters for XDS data reduction, to monitor the progress of the program, and to discover bugs or regressions.


PulG (good 2-wavelength MAD data @ 2.8 A)

Raw data: ftp://turn5.biologie.uni-konstanz.de/pub/datasets/

Reference: Köhler, R., Schäfer, K., Müller, S., Vignon, G., Diederichs, K., Philippsen, A., Ringler, P., Pugsley, A.P., Engel, A., Welte, W. (2004) Structure and assembly of the pseudopilin PulG. Molecular Microbiology 54, 647-664. [1]

XDS.INP for remote high data

JOB=XYCORR INIT COLSPOT IDXREF DEFPIX INTEGRATE CORRECT

! for this experiment:
ORGX=1031 ORGY=1001
DETECTOR_DISTANCE=220
OSCILLATION_RANGE=1
X-RAY_WAVELENGTH=0.97857
NAME_TEMPLATE_OF_DATA_FRAMES=images/pulg_semet_D22_2_???.img DIRECT  TIFF
DATA_RANGE=5 124
SPOT_RANGE=5 124
SPACE_GROUP_NUMBER=179
UNIT_CELL_CONSTANTS= 85.5   85.5  145.2  90 90 120

FRIEDEL'S_LAW=FALSE
STRICT_ABSORPTION_CORRECTION=TRUE

! parameters with changes wrt default values:
VALUE_RANGE_FOR_TRUSTED_DETECTOR_PIXELS=8000. 30000.
MINIMUM_ZETA=0.05
INCLUDE_RESOLUTION_RANGE=50 0
STRONG_PIXEL=6
BACKGROUND_RANGE=1 10

! parameters specifically for this detector and beamline:
NX=2048 NY=2048 QX=0.079092  QY=0.079092   !MARCCD 165mm version
DETECTOR=CCDCHESS        MINIMUM_VALID_PIXEL_VALUE=0     OVERLOAD=65000
DIRECTION_OF_DETECTOR_X-AXIS=1 0 0
DIRECTION_OF_DETECTOR_Y-AXIS=0 1 0
INCIDENT_BEAM_DIRECTION=0 0 1
ROTATION_AXIS=1 0 0
FRACTION_OF_POLARIZATION=0.99
POLARIZATION_PLANE_NORMAL=0 1 0

XDS.INP for inflection point data

same as above, except

X-RAY_WAVELENGTH=0.97972
NAME_TEMPLATE_OF_DATA_FRAMES=images/pulg_semet_D22_3_???.img DIRECT  TIFF
DATA_RANGE=1 120
SPOT_RANGE=1 120