IDXREF prints !!! WARNING !!! message
== XDS crashes ==
XDS should never crash (if it terminates with an error message, this does not count as crash). If it does, it is either a bug in the program which should be brought to the attention of Wolfgang Kabsch or Kay Diederichs, and will be fixed, or it is a problem with your computer, or (rarely) it is due to improper inputs ([[Problems#INTEGRATE_cell_and.2For_distance_run_away.3B_xds_crashes_or_has_to_be_killed|this]] is the only example I know of).
If it crashes for the second reason, these are the things to try/consider:
THE "DATA_RANGE=" IN FILE "XDS.INP" AND START ALL OVER AGAIN.
This is printed out for you to actually read, and take action accordingly. In most cases you just change the JOBS - JOB= line in XDS.INP to read
JOB= DEFPIX INTEGRATE CORRECT
and then continue to run XDS. In other cases you may want to change SPOT.XDS, or other keywords in [[XDS.INP]] (see also below). But in any case this is an important alert that should make you check the correctness of the parameters that describe the data collection (X-RAY_WAVELENGTH, DETECTOR_DISTANCE, ORGX, ORGY, OSCILLATION_RANGE, NAME_TEMPLATE_OF_DATA_FRAMES).
=== Difference vectors are neither integers nor halfs === This can happen if SPACE_GROUP_NUMBER is wrong, i.e. the user "forces" a lattice (e.g. body-centered) that does not match the true one (which may be primitive). So the first thing to try is SPACE_GROUP_NUMBER=0. Sometimes, IDXREF nevertheless finds no good lattice:
# COORDINATES OF VECTOR CLUSTER FREQUENCY CLUSTER INDICES
6 0.0098829 0.0070246-0.0042191 1430. 0.50 -0.50 -0.44 <---- same here
7 -0.0030325 0.0110238 0.0056577 1422. -0.50 0.50 -0.44 <---- and here
...
If it is not a case of SEPMIN and CLUSTER_RADIUS being too large (see above), try to increase INDEX_ERROR - in this case, it indexes beautifully with INDEX_ERROR=0.14 .
If this does not help, try to refine even less items, e.g. leave out AXIS.
 
=== IDXREF prints ERROR IN REFINE !!! RETURN CODE IS IER= 0 ===
 
This is due to either wrong inputs in XDS.INP, or due to bad data, e.g. spots from many crystals whose diffraction patterns overlap. The first possibility applies if the diffraction pattern is clean. The second applies if the diffraction pattern is ugly, and unsuitable for indexing. In that case, maybe try a different SPOT_RANGE.
=== IDXREF.LP does not show the expected lattice ===
== Integration failure ==
=== INTEGRATE stops with error message ===
If INTEGRATE stops after e.g.
******************************************************************************
BEAM_DIVERGENCE= BEAM_DIVERGENCE_E.S.D.=
then there are two ways to resolve this:* you could insert a line DELPHI=10 (or DELPHI=20, for 10 or 20 degrees batches; the default is 5 degree batches) into XDS.INP and re-run INTEGRATE* as the error message suggests, you should reduce the upper limit of the DATA_RANGE, to stop before the problematic frames, and re-run INTEGRATE. In this example, you would modify XDS.INP to have
DATA_RANGE=1 135
JOB=INTEGRATE CORRECT
Save XDS.INP, run XDS and inspect INTEGRATE.LP, to find the lines (e.g.)
BEAM_DIVERGENCE= 0.478 BEAM_DIVERGENCE_E.S.D.= 0.048
REFLECTING_RANGE= 1.100 REFLECTING_RANGE_E.S.D.= 0.157
Copy them to XDS.INP. Restore the original DATA_RANGE and continue.
 
If this problem happens with multiple XDS jobs working on the same data set, you might also get a message like
.../bin1_02.tmp
Image PC Routine Line Source
xds_par 0000000000592B91 Unknown Unknown Unknown
xds_par 00000000004BEF21 joinintegrate_ 8995 MAIN_XDS.f90
xds_par 0000000000410A5B xds_ 21690 MAIN_XDS.f90
xds_par 000000000040B3A4 MAIN__ 1 MAIN_XDS.f90
xds_par 00000000004083F6 Unknown Unknown Unknown
libc.so.6 00007FB40222E830 Unknown Unknown Unknown
xds_par 00000000004082E9 Unknown Unknown Unknown
which looks like a real crash of the program, but in this case with a known reason.
Another error mode of INTEGRATE (in processing of small-molecule data) is ...
The error message is misleading in this case: there are too few reflections to build the average profile. The fix is: restart INTEGRATE after inserting e.g.
DELPHI=20 ! default is 5, so try with e.g. 10, 20, 45, 90, 180
in XDS.INP and re-run INTEGRATE. === INTEGRATE cell and/or distance run away; xds crashes or has to be killed ===If during INTEGRATE the cell keeps increasing or the distance decreasing or both, then xds starts to consume large amounts of memory and becomes very slow. This may finally exhaust all available memory, and the job either crashes or has to be killed by the user. The fix here is to use REFINE(INTEGRATE)= BEAM POSITION ORIENTATION ! CELL instead of (what used to be the default until June 2017) REFINE(INTEGRATE)= BEAM POSITION ORIENTATION CELL Quite generally, the more conservative setting without CELL refinement is adequate unless your crystals diffract to quite high resolution. A sure sign that you should not be refining CELL is that the refined cell and/or distance values in INTEGRATE.LP fluctuate without obvious physical reason. Moreover, distance ("POSITION") refinement nicely soaks up any cell change resulting from radiation damage. A compromise (if you suspect that the cell parameters actually change ''differently'') would be REFINE(INTEGRATE)= BEAM ORIENTATION CELL ! POSITIONThis should also avoid the run-away but gives more freedom to the refinement. Of course it requires a refined distance (from IDXREF, or rather from GXPARM.XDS->XPARM.XDS renaming).