Refinement: Difference between revisions

From CCP4 wiki
Jump to navigation Jump to search
Line 54: Line 54:


If you are really desperate, another option could be to use harmonic restraints in [[CNS]] to keep your backbone fairly fixed in parts of the map where you believe the secondary structure is correct (most likely alpha-helices). You could also fix main-chain elements completely (in any refinement program), but it is definitely preferable to leave some room for change in the xyz positions, and harmonic restraints are a nice way of doing exactly that.
If you are really desperate, another option could be to use harmonic restraints in [[CNS]] to keep your backbone fairly fixed in parts of the map where you believe the secondary structure is correct (most likely alpha-helices). You could also fix main-chain elements completely (in any refinement program), but it is definitely preferable to leave some room for change in the xyz positions, and harmonic restraints are a nice way of doing exactly that.
=== Bulk solvent correction produces difference density ===
Sometimes people observe strong residual difference density in a cavity of the protein. E.g. there was a paper by Brian Matthews' group (Marcus D. Collins, Michael L. Quillin, Gerhard Hummer, Brian W. Matthews, Sol M. Gruner, Structural Rigidity of a Large Cavity-containing Protein Revealed by High-pressure Crystallography, Journal of Molecular Biology, Volume 367, Issue 3, 30 March 2007, Pages 752-763, [http://dx.doi.org/10.1016/j.jmb.2006.12.021]) on a high pressure form of lysozyme where they found a large hydrophobic void. Bulk water could only be compelled to enter the void by application of very high external pressure.
Bulk solvent mask artifacts can only occur at narrow channels, where the mask radius is too big to define the channel as belonging to the bulk solvent region, leaving it "empty" and thus resulting in ''positive'' difference density.
The following advice is specific for [[ccp4dev:Refinement_with_Refmac5|Refmac]]: Changing from simple scaling to Babinet scaling is an important check to exclude mask bulk solvent artifacts, but there, you have to uncheck the "calculate contribution from the solvent region", because this is done by the Babinet scaling, already.
For [[Phenix|phenix.refine]], the bulk solvent mask may be varied - see [http://www.phenix-online.org/documentation/refinement.htm#anch52].
In the case of ''negative'' difference density in a big hydrophobic cavity, one possible reason for a negative difference density are underestimated magnitudes of |Fobs| at very low resolution, either because they are weakened by the beam-stop (half-)shadow, or because they are overloads that have been poorly extrapolated. A simple check for wrongly determined low-resolution |Fobs| is to cut your low resolution data during refinement at a somewhat higher resolution, say 20 A instead of 80 A, and see whether the negative difference density disappears. If, yes, you should check your data processing again.
The other possibility of course is that the data is good, that this is an accurate experimental result and there really is a void, or at least a cavity where the mean bulk density is lower than in bulk water.  One way to test the void theory would be to fill the cavity with O atoms of zero (or very small, say 0.01) occupancy.  Hopefully (!) that will prevent Refmac filling the cavity with bulk solvent.  One could then try giving these O atoms large B factors, say 200, to smear them out, and then increase the occupancies to titrate the actual bulk density.

Revision as of 12:58, 2 June 2009

Theory

For now, see http://www.usm.maine.edu/~rhodes/ModQual/index.html#RefineXray

Programs

restraints for ligands

All refinement programs come with a set of ligands known to them, i.e. the files describing the topology and parameters of these ligands are part of the distribution. Both Refmac and phenix.refine use one large file called mon_lib_list.cif . CNS uses files in the $CNS_TOPPAR directory.

If you have a ligand that is unknown to the refinement program, you could either

  • identify a similar ligand among the known ones and modify it
  • use the PRODRG server to obtain the ligand description
  • use G. Kleywegt's HIC-Up to obtain the ligand description
  • try to identify the ligand in the list of chemical compounds occurring in PDB files, at http://www.wwpdb.org/ccd.html - maybe it is known under a different name than you thought, and you just have to adjust your PDB file

what can go wrong in refinement?

R-factor does not go down

If this happens in the R-factor range of 30-40, here are a couple of possible reasons:

help, my protein has high B-factors!

This is also a FAQ on CCP4BB. The answer is: there's probably nothing wrong with it. If your crystals diffract to 3 A at a synchrotron, then the average B-factor should most likely be on the order of 100 A^2. If your crystals diffract to 2 A, then the average B-factor is most likely on the order of 40 A^2 or so. Use B. Rupp's calculator ([1]) to find out the dependance of scattering power on B-factor.

R_free much higher than R

how large should the difference between R_free and R be?

For now, see Kleywegt GJ, Jones TA."Homo crystallographicus--quo vadis?" Structure. 2002 Apr;10(4):465-72.

Wrong space group

Sometimes crystal symmetry combines with non-crystallographic symmetry (NCS) and produces a diffraction pattern resembling higher symmetry space group than what you really have. NCS in this case closely resembles crystallographic symmetry. If resolution is not high enough, the difference in spot positions may be too small to give any detectable problems with indexing, integration and scaling. Even phasing (e.g. molecular replacement) may be successful. But if your R-factor hangs fairly high and you have problems building parts of your structure, it is worth trying to check other space groups. The most straightforward approach is to try processing data in P1, because if that does not bring R-factor down significantly, other space group choices will not solve the problem either.

This occurs most often at moderate resolution. However, the structure of the ketosteroid isomerase had to be refined in P1 at atomic resolution, although it refines well in C2221 at lower resolution such as 1.5A.

Refining low resolution structures

Maintaining the secondary structure of your model when refining against weak data can be really challenging. There are some options, but in the end you might have to accept a fairly large number of Ramachandran plot outliers.

Try phenix.refine with the keyword "discard_psi_phi=False". Then the psi and phi dihedral angles should be restrained according to the CCP4 monomer library definitions. There was a discussion of it in the phenixbb in July 2007. Also see the discussion in the ccp4bb from December 2006.

Remember that phi-psi angles are excellent for validation purposes but only when they are unrestrained. If you restrain them, you lose this option!

You can also try restraining alpha-helices hydrogen bonding, and beta-sheet cross-strand hydrogen bonds. This can be done in REFMAC, phenix.refine and CNS (it's documented for all of them).

If you are really desperate, another option could be to use harmonic restraints in CNS to keep your backbone fairly fixed in parts of the map where you believe the secondary structure is correct (most likely alpha-helices). You could also fix main-chain elements completely (in any refinement program), but it is definitely preferable to leave some room for change in the xyz positions, and harmonic restraints are a nice way of doing exactly that.

Bulk solvent correction produces difference density

Sometimes people observe strong residual difference density in a cavity of the protein. E.g. there was a paper by Brian Matthews' group (Marcus D. Collins, Michael L. Quillin, Gerhard Hummer, Brian W. Matthews, Sol M. Gruner, Structural Rigidity of a Large Cavity-containing Protein Revealed by High-pressure Crystallography, Journal of Molecular Biology, Volume 367, Issue 3, 30 March 2007, Pages 752-763, [2]) on a high pressure form of lysozyme where they found a large hydrophobic void. Bulk water could only be compelled to enter the void by application of very high external pressure.

Bulk solvent mask artifacts can only occur at narrow channels, where the mask radius is too big to define the channel as belonging to the bulk solvent region, leaving it "empty" and thus resulting in positive difference density.

The following advice is specific for Refmac: Changing from simple scaling to Babinet scaling is an important check to exclude mask bulk solvent artifacts, but there, you have to uncheck the "calculate contribution from the solvent region", because this is done by the Babinet scaling, already.

For phenix.refine, the bulk solvent mask may be varied - see [3].

In the case of negative difference density in a big hydrophobic cavity, one possible reason for a negative difference density are underestimated magnitudes of |Fobs| at very low resolution, either because they are weakened by the beam-stop (half-)shadow, or because they are overloads that have been poorly extrapolated. A simple check for wrongly determined low-resolution |Fobs| is to cut your low resolution data during refinement at a somewhat higher resolution, say 20 A instead of 80 A, and see whether the negative difference density disappears. If, yes, you should check your data processing again.

The other possibility of course is that the data is good, that this is an accurate experimental result and there really is a void, or at least a cavity where the mean bulk density is lower than in bulk water. One way to test the void theory would be to fill the cavity with O atoms of zero (or very small, say 0.01) occupancy. Hopefully (!) that will prevent Refmac filling the cavity with bulk solvent. One could then try giving these O atoms large B factors, say 200, to smear them out, and then increase the occupancies to titrate the actual bulk density.